Display
Design of display STN
Screen diagonal 10.4 in
Size 10.4"
Display type STN, 256 colors
Color type Colors
Resolution (pixels)
Horizontal image resolution 640
Vertical image resolution 480
Resolution (WxH in pixel) 640 x 480
Backlighting
MTBF backlighting (at 25 °C) about 60,000 hours
Control elements
Control elements Membrane keyboard
Operating options Keys
Function keys, programmable 36 function keys, 28 with LEDs
Connection for mouse/keyboard/barcode reader USB / USB / USB
Keyboard fonts
freely inscribable membrane keys Yes
Number of function keys with LEDs 28
Numeric/alphabetical input Yes / Yes
hexadecimal keyboard Yes
Multi-key operation Yes
Touch operation
Touch screen No
Special operator controls
Handwheel No
Supply voltage
Supply voltage 24 V DC
UPS connectable (serial) Yes
Input current
Rated current 0.9 A
Processor
Processor RISC 32-bit
Processor type RISC 32-bit
Memory
Type Flash / RAM
Usable memory for user data 2048 KB usable memory for user data
Battery
Backup battery
Backup battery optional 3.6 V
minimum backup duration 3 a
Type of output
Info LED Yes
Power LED No
Error LED No
Drives
Diskette drive No
Time of day
Clock
Type Hardware clock, battery backup, synchronizable
battery-backed and synchronizable Yes
Interfaces
Interfaces 2 x RS232, 1 x RS422, 1 x RS485 (max. 12 Mbit/s)
Number of RS 485 interfaces 1
Transmission rate, max. 12 Mbit/s
USB port 1 x USB
PC card slot No
CF card slot 1 x CF card slot
Multi Media Card slot No
Special interfaces No
Industrial Ethernet
Industrial Ethernet interface No
Degree and class of protection
Front IP65
Type of protection IP20
IP (at the front) IP65
Rear IP20
Standards, approvals, certificates
Certifications CE, GL, ABS, DNV, LRS, FM Class I Div. 2, UL, cULus, EX Zone 2/22, C-TICK
Ambient conditions
Mounting position vertical
maximum permissible angle of inclination without external ventilation +/- 35 °
Storage/transport temperature
Transport, storage -20 °C to +60 °C
Relative humidity
max. relative humidity 90 %
Operating systems
Operating system Windows CE
Configuration
Configuration software
Configuration tool ProTool Version 6 SP 3 or higher, or WinCC flexible Standard Version 2004 or higher (to be ordered separately)
1st configuration kit ProTool
Version Version 6 SP 3
Configuration tool ProTool
2nd configuration kit WinCC flexible Standard
Version Version 2004
Configuration tool WinCC flexible
Type Standard
Languages
Online languages
Number of online/runtime languages 5
Languages
Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Visual Basic Scripts
Debugging in the simulator No
Task planner Yes
Help system Yes
Number of characters per info text 70
Number of tooltips 0
With alarm logging system (incl. buffer and acknowledgment)
Number of alarm classes 32
Number of messages 4000
Bit messages Yes
Analog messages Yes
Number of bit messages 2000
Number of analog messages 2000
Telegram message procedure Alarm S Yes
System messages HMI Yes
System messages PLC No
System messages, other (SIMATIC S7, Sinumerik, Simotion, ...) No
Message length (in characters) 70
Lines 1
Number of process values per message 8
Acknowledgment groups Yes
Message indicator Yes
Acoustic feedback No
First/last value Yes
Recipes
Number of recipes 300
Data records per recipe 500
Entries per data record 1000
Recipe memory 64 KB integrated Flash, expandable
Variables
Number of variables per device 2048
Number of variables per screen 200
Limit values Yes
Multiplexing Yes
Structs Yes
Type Date & Time 2048
Images
Number of configurable images 300
Permanent window/default Yes
Start screen configurable Yes
Image selection by PLC Yes
Image number in the PLC Yes
Image objects
Text objects 10,000 text elements
Fields per image 200
Date/time fields 30
Index of screen context No
Return Yes
Graphics object Bit maps, icons, vector graphics
Icons 1000
Icon (full screen) 0
Complex image objects
Status/control With SIMATIC S7
dynamic objects Diagrams, bar graphs, invisible buttons
Number of objects per project 500
Number per image 5
Methods Trend
Limit value lines Yes
Number of bars per chart 10
Limit value lines Yes
alphanumeric fields 1000
alphanumeric fields per image 100
numerical fields 1000
numerical fields per image 100
Password errors 1000
Number of slides per image 0
Number of analog indicators per image 0
Number of visible switches per project 1000
visible switches per image 100
hidden switches per image 100
Number of status switches per project 1000
Button status switches per image 100
Number of selector switches per project 1000
Selector switches per image 100
Number of decade switches per project 0
Decade switches per image 0
Number of signal lamps per project 1000
Signal lamps per image 100
Attributes for dynamic objects
Color change Yes
X/Y movement Yes
Hide Yes
Lists
Number of text lists per project 500
Number of entries per text list 256
Number of graphics lists per project 400
Number of graphic lists per image 10
Number of entries per graphics list 255
Archiving
Number of archives per device 20
Number of measuring points per project 20
Number of entries per archive 10000
Message archive Yes
Process value archive Yes
Archiving methods Sequence archive, circular log, alarm log, process value archive
Sequential archive Yes
Short-term archive Yes
Memory location CF card, Ethernet
PC card No
CF card Yes
USB memory No
Ethernet Yes
Data storage format CSV file, readable, e.g. with MS Excel, MS Access
CSV Yes
TXT No
external evaluation Readable, e.g. with MS Excel, MS Access, etc.
Size of archive depending on free memory on ext. card/stick or on free hard disk space via network drive
Online evaluation Using trend curves
Using trend curves Yes
Filters
cyclic Yes
Tolerance Yes
Change Yes
Security
Number of user groups 50
Number of user rights 32
Password export/import Yes
Logging through printer
Recording/Printing Alarms, report (shift report), color print, hardcopy
Transfer (upload/download)
Transfer of configuration MPI/PROFIBUS DP, serial, USB, Ethernet, automatic transfer recognition
Process coupling
Connection to controller S5, S7-200, S7- 300/400, TI 505, Win AC, PC (TCP/IP), SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), Telemecanique (ADJUST), OMRON (LINK/Multilink), Modicon (Modbus), for further non-Siemens drivers, see section on "System interfaces"
S7-200 Yes
PPI (point-to-point) Yes
PPI network No
MPI Yes
PROFIBUS DP Yes
S7-300/400 Yes
MPI Yes
PROFIBUS DP Yes
PROFINET No
S5 Yes
serial Yes
PROFIBUS DP Yes
TI 505 Yes
Allen Bradley (DF1) Yes
Allen Bradley (DF485) Yes
Mitsubishi (FX) Yes
Mitsubishi (MP4) Yes
Telemechanique (ADJUST) Yes
Telemecanique (Uni-Telway) Yes
OMRON (LINK/Multilink) Yes
Modicon (Modbus) Yes
GE-Fanuc (SNP) Yes
Functions
Key repeat No
TAB sequence Yes
Calculating functions Yes
Animate Yes
Menu tree editor No
Unit switchover No
Service tools/configuration aids
Clean screen No
Touch calibration No
Backup/restore Yes
Simulation Yes
Device switchover Yes
Delta transfer Yes
Monitoring function for battery and memory Yes
Trace (operation archive) No
Expandability/openness
Open Platform Program Yes
I/O / Options
I/O devices Printer, barcode reader
Dimensions
Front of enclosure (W x H) 483 mm x 310 mm
Weight
Weight (without packaging) 6 kg
other
free hotline Yes
Warranty period 1 a
Information for market places
CD-ROM No
Hard disk No

Porównaj ofertę z innymi dostawcami

To proste! Uzupełnij formularz i poznaj najlepsze oferty dostawców z branży automatyki przemysłowej.

Dystrybutor

ALLMAR Automatyka Przemysłowa, Dystrybutor Automatyki SIEMENS

Adres: Krotoszyńska 11, 61-315 Poznań

Nr telefonu: (061)8799776 Skopiuj

Nr telefonu: (061)8705438 Skopiuj

Faks: (061)8799776 Pokaż numer Skopiuj

Przy kontakcie powołaj się na portal automatyka.pl